Progress of with the development of society , science and technology and gradual improvement of people's living standard, various kinds of help automatic control system in life begin to enter people's life, the system of automatically-controlled door taking one-chip computer as the core is one of them. Indicate too that the automatic controlled field became a member in digitized era at the same time. Its practicability is strong, multiple functional, modern techniques, make people believe this is an achievement of scientific and technological progress. It lets the mankind understand even more, the development in digital era will change human life, will quicken the development of science and technology.
Through the research and design to the thing that "the single-chip computer controls the system of automatically-controlled fireproof rolling door" , have written the computer and controlled the systematic thesis of automatically-controlled door meticulously. Thesis this is it rely mainly on single-chip computer to explain emphatically, LED lattice show chip and walk into electrical machinery central systems.
Is it use AT89C51 as core of controlling , LED lattice show chip , walk into electrical machinery ,smoke sensor and temperature sensor , electric potential system that device combine together mainly to design originally. Give full play to the performance of the one-chip computer. Its advantage hardware circuit is simple, the software is with perfect function, the control system is reliable , higher characteristic of the sex price, have certain use and reference value.
Keywords single-chip computer fireproof rolling gate sensor
fire alarm
目 录
第一章 绪 论........................................................ 1
1.1 选题背景...................................................... 1
1.2 智能火灾报警系统.............................................. 1
1.3 火灾探测器.................................................... 2
第二章 总体设计及方案论证............................................ 5
2.1 工艺技术要求.................................................. 5
2.2 系统设计思想.................................................. 5
2.3 方案论证...................................................... 6
第三章 单片机AT89C51原理............................................ 8
3.1 引脚说明...................................................... 8
3.2 工作特性..................................................... 11
第四章 前向通道的设计............................................... 17
4.1 温度传感器................................................... 17
4.2 烟雾传感器................................................... 18
4.3 运算放大器AD595.............................................. 20
4.4 A/D转换器.................................................... 21
4.5 8255扩展..................................................... 24
4.6 键盘显示..................................................... 27
4.7 系统电源..................................................... 28
第五章 后向通道的设计............................................... 30
5.1 卷帘门电机正反转控制......................................... 30
5.2 自动喷淋控制................................................. 31
5.3 显示部分..................................................... 32
5.4 报警电路..................................................... 35
第六章 软件设计..................................................... 38
6.1 设计思想..................................................... 38
6.2 流程图....................................................... 40
第七章 结束语....................................................... 49
致 谢.............................................................. 50
参考文献.............................................................. 51
附表A................................................................. 52
附表B................................................................. 53
第一章 绪 论
1.1 选题背景
近年来全国火灾事故频繁发生,造成人、财、物的巨大损失。用户对火灾报警以至自动消防系统的要求越来越高。针对多起火灾事故的分析,排除水压不足等因素外,现有的消防隔断未能起到应有的作用,是造成重大损失的关键。
本文基于上述考虑,通过研发全自动智能防火卷闸门电气控制系统,满足了防火卷闸门的各种动作状态要求,也满足了用户的不同使用环境的需要。其主要功能是在火灾发生时,控制防火卷闸门可靠、准确地运行,实现防火卷闸门的一步降或二步降,达到分区防火,控制火势蔓延,减少火灾损失的目的防火卷闸门控制方式主要分为手动调整自动与联动等各种控制方式同时预留和上位机的通讯接口,为自动消防系统作好前期准备。
同时,通过温度传感器和烟雾传感器检测出信号,通过控制电路使电话自动拨号(119),并报告现场地址。这对有效、快速扑救具有积极意义。本系统适用于各种消防环境,尤其适合于不能用水做灭火介质的地方,如图书馆、档案馆、计算机房等处。因单片机集成度高,故该装置具有结构简单,可靠性高,成本低等优点。
1.2 智能火灾报警系统
火灾自动报警系统属于楼宇自动化范畴,是当前楼宇自动化的一个主要构成系统。其设置目的是为了防止和减少火灾危害,保护人身和财产安全。火灾报警技术是预防火灾的一项基础工作,应用范围广泛。报警早,损失少,不仅对发生火灾的单位和个人具有重要作用,而且对公安消防监督机构及时扑灭火灾、减少人员伤亡和财产损失同样具有十分重要的现实意义。
火灾自动报警系统由触发器件、火灾报警装置、火灾警报装置及具有其他辅助功能的装置组成。随着电子技术和计算机技术的迅速发展,火灾自动报警系统的结构、形式越来越灵活多样,很难精确划分为几种固定的模式。火灾自动报警技术趋向于智能化系统,这种系统可组合成任何形式的火灾自动报警网络形式,既可以是区域报警系统,又可以是集中报警系统或控制中心报警系统形式。
所谓智能火灾自动报警系统,应当是:使用探测器件将火灾发生期间所产生的烟、温、光等信号以模拟量形式,连同外界相关的环境参数一起传送给报警器,报警器再根据获取的数据及内部存储的大量数据,利用火灾模型判据来判断火灾是否存在,这样的系统称为智能火灾自动报警系统。由于该系统为解决火灾报警系统存在的两个难题(误报、漏报)提供了新的方法和手段,并在处理火灾真伪方面表现出明显的有效性和创新性,这是火灾自动报警系统在技术上的飞跃。从传统型走向智能型,是国内外火灾自动报警系统技术发展的必然趋势。